Gas regulation station and gas boiler room
Gas regulation station
Our company supplies gas regulation stations (RS) in a wide range of capacities and pressure levels according to the customer's needs. Most deliveries are made in the form of a higher turnkey supplier function.
We ensure with our own forces:
- Processing of the project documentation of the machine part of the control station and the heat source for gas preheating
- Processing of project documentation of the electrical part of the control station including electrical switchboards, LV power distribution, M&C, remote data transmissions and operation control (telemetry), lightning rods, grounding, connection and LV cable connection
- Production and installation of the technology of mechanical and electrical parts of the control station in a technological cabinet or building
- Carrying out the prescribed tests
- Delivery of construction part of RS including cladding or building, fencing, paved surfaces, landscaping and access roads
- Carrying out the prescribed tests of the mechanical and electrical parts of the control station
- Operator training and put into operation
- Carrying out regular inspections of the control station
- Carrying out repairs and maintenance of the control station
We use gas filters, electric gas pre-heaters, electric switchboards and hot water exchangers with performance parameters for ordinary regulation stations used in the distribution networks of gas companies or industrial customers for the delivery of control stations.
A brief overview of the regulation stations implemented by our company so far:
VVTL/VTL pre-regulation station (8 buildings in total):
Gas inlet pressure: 4.5 – 6.3 MPa
Gas output pressure: 1.7 – 2.5 MPa
Gas flow: 80,000 to 160,000 Nm3/h
VTL/STL control station (more than 80 buildings):
Gas inlet pressure: 1.7 – 4.0 MPa
Gas output pressure: 0.1 – 0.4 MPa
Gas flow: 200 to 100,000 Nm3/h
STL/NTL control station (more than 40 buildings):
Gas inlet pressure: 0.1 – 0.4 MPa
Gas outlet pressure: 2.1 kPa
Gas flow: 100 to 4000 Nm3/h
VTL/STL RESO (almost 20 buildings):
Gas inlet pressure: 1.7 – 4.0 MPa
Gas outlet pressure: 100 to 400 kPa
Gas flow: max. 650 Nm3/h
Block regulation device (BRZ) and booster regulation device (PRZ):
BRZ: PRZ:
Gas inlet pressure: 0,1 – 0,4 MPa 0,1 – 0,4 MPa
Gas outlet pressure: 2,1 kPa 2,1 kPa
Gas flow: max. 300 Nm3/h max. 500 Nm3/h
STL/NTL underground control station (more than 15 structures):
Gas inlet pressure: 0,1 – 0,4 MPa
Gas outlet pressure: 2,1 kPa
Gas flow: 470 až 2000 Nm3/h
VVTL/NTL control kits:
Gas inlet pressure: 1,7 – 10,0 MPa
Gas outlet pressure: I. stupeň: 300 kPa
II stupeň: 2,1 kPa
Gas flow: 20 - 100 Nm3/h
Gas boiler rooms
Our company supplies gas boiler rooms and rooms with gas boilers mainly as part of deliveries of gas regulation stations, where they are used as a heat source for preheating gas in heat water exchangers before reducing the gas pressure to a lower value.
GAS BOILER PLANTS IN LARGE CAPACITY GAS REGULATORY STATIONS:
ROOM WITH GAS BOILERS IN A LOWER POWER GAS REGULATION STATION: